For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus D is installed in a suspended grid system, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are easily demountable.
SYSTEM RANGE| Size, mm | 600 X 600 |
1200 X 600 |
1200 X 1200 |
XL 1600 X 600 |
XL 1600 X 600 |
XL 2000 X 600 |
XL 2400 X 600 |
| T24 | • | • | • | • | • | • | • |
| Thickness | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| Inst. diagr. | m97 m92 |
m97 m92 |
m93 | m17 m92 m97 |
m17 m92 m97 |
m17 m92 m97 |
m17 m92 m97 |
SYSTEM AND PRODUCT DESCRIPTION
The systems consist of Ecophon Focus D tiles and Ecophon Connect grid systems, with an approximate weight of 3-4 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are painted. The grid is manufactured from galvanized steel. The system is patented in the US, and patent pending in Europe.
ACOUSTICS:
SOUND ABSORPTION: Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,c,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=180 according to ASTM E 1111 and E 1110.
α Practical sound absorption coefficient

| Product | Focus D | |||
| O.d.s. mm | 400 | 200 | 75 | 60 |
| Absorption class | A | A | B | |
| NRC | 0,8 | 0,9 | ||
| S A A | 0,82 | 0,9 | ||
Focus D tile

Section of Focus D system

Focus D system

The individual tiles are easily demountable
Technical info
ACCESSIBILITY: The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection). Colours: See Ecophon colour range.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: CCertified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
| Country | Standard | Class |
| UK | BS 476 Parts 6&7 | Class 0 |
| Europe | EN 13501-1 | A2-s1,d0 |
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
| Inst. diagr., Size (mm) | Max live load (N) | Min load bearing capacity (N) |
| m92 2400x600 | 50 | 160 |
| m17 1800x600 | 20 | - |
| m17 2400x600 | 0 | - |
| m92 1800x600 | 50 | 160 |
| m92 2000x600 | 50 | 160 |
| m97 600x600 | 40 | - |
| m97 2400x600 | 50 | 160 |
| m17 1600x600 | 40 | - |
| m93 1200x1200 | 50 | 160 |
| m97 1600x600 | 10 | - |
| m97 2000x600 | 50 | 160 |
| m17 2000x600 | 10 | - |
| m92 120x600 | 50 | 160 |
| m92 1600x600 | 50 | 160 |
| m92 1600x600 | 50 | 160 |
| m97 1200x600 | 50 | 160 |
| m97 1800x600 | 50 | 160 |
INSTALLATION: Installed according to installation diagram M92, M93, M97 or M17, which include information regarding minimum overall depth of system. Since the tiles need precise positioning, integration of services requires extra care during design and installation in order to achieve a good end result.
Installation Guides (pdf)
| Size, mm | 600 X 600 |
1200 X 600 |
1200 X 1200 |
XL 1600 X 600 |
XL 1600 X 600 |
XL 2000 X 600 |
XL 2400 X 600 |
| T24 | • | • | • | • | • | • | • |
| Thickness | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| Inst. diagr. | m97 m92 |
m97 m92 |
m93 | m92 m97 |
m92 m97 |
m92 m97 |
m92 m97 |
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
| Quantity specification (excl. wastage) Installation diagram (M92) for Focus D 600x600, 1200x600 mm and Focus D XL. Suspended installation |
Size, mm | |||||
| 600x600 | 1200x600 | 2000x600 | 1600x600 | 1800x600 | 2400x600 | |
| Focus D | 2.8/m² | 1.4/m² | 0.85/m² | 1.05/m² | 0.95/m² | 0.7/m² |
| 1 Connect T24 Main runner HD 7101, installed at 600 mm centres | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² |
| 2 Connect Wall bracket T-profile 0524 | 1 for every suspended row of Main runner |
1 for every suspended row of Main runner |
1 for every suspended row of Main runner |
1 for every suspended row of Main runner |
1 for every suspended row of Main runner |
1 for every suspended row of Main runner |
| 3 Connect Space bar 0520, installed at 1500 mm centres (max. distance from wall 300 mm) | 0.7 m/m² | 0.7 m/m² | 0.7 m/m² | 0.7 m/m² | 0.7 m/m² | 0.7 m/m² |
| 4 Connect Wall bracket Space bar 0525 | 1 for every row of Space bar |
1 for every row of Space bar |
1 for every row of Space bar |
1 for every row of Space bar |
1 for every row of Space bar |
1 for every row of Space bar |
| 5 Connect Stop clip | 2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
| 6 Connect Split pin 0523, installed one per joint Main runner/Space bar | 1.4/m² | 1.4/m² | 1.4/m² | 1.4/m² | 1.4/m² | 1.4/m² |
| 7 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm) | 0.7/m² | 0.7/m² | 0.7/m² | 0.7/m² | 0.7/m² | 0.7/m² |
| 8 Connect Hanger clip | 0.7/m² | 0.7/m² | 0.7/m² | 0.7/m² | 0.7/m² | 0.7/m² |
| 9 Connect Angle trim, fixed at 300 mm centres | as required | as required | as required | as required | as required | as required |
| 10 Connect Shadow-line trim, fixed at 300 mm centres | as required | as required | as required | as required | as required | as required |
| Quantity specification (excl. wastage) Installation diagram (M17) for Focus D XL in corridors |
Size, mm | |||
| 1600x600 | 1800x600 | 2000x600 | 2400x600 | |
| Focus D | 1.05/m² | 0.95/m² | 0.85/m² | 0.7/m² |
| 1 Connect T24 Corridor profile, installed at 600 mm centres | 1.05/m² | 0.95/m² | 0.85/m² | 0.7/m² |
| 2 Connect End fixing plate 0192 | 2.1/m² | 1.9/m² | 1.7/m² | 1.4/m² |
| 3 Connect Angle trim, fixed at 200 mm centres | as required | as required | as required | as required |
| 4 Connect Shadow-line trim, fixed at 200 mm centres | as required | as required | as required | as required |
| Quantity specification (excl. wastage) Installation diagram (M93) for Focus D 1200x1200 mm |
Size, mm |
| 1200x1200 | |
| Focus D | 1200x1200 |
| 1 Connect T24 Main runner HD 7101, installed at 1200 mm centres | 0.9 m/m² |
| 2 Connect Wall bracket T-profile 0524 | 1 for every row of Main runner |
| 3 Connect Space bar 0520, installed at 1500 mm centres (max. distance from wall 300 mm) | 0.7 m/m² |
| 4 Connect Wall bracket Space bar 0525 | 1 for every row of Space bar |
| 5 Connect Edge stiffener 0346 | 1.4/m² |
| 6 Connect Stop clip | 2 for every row of Main runner |
| 7 Connect Split pin 0523, installed one per joint Main runner/Space bar | 0.85/m² |
| 8 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm) | 0.7/m² |
| 9 Connect Hanger clip | 0.7/m² |
| 10 Connect Angle trim, fixed at 300 mm centres | as required |
| 11 Connect Shadow-line trim, fixed at 300 mm centres | as required |
| Quantity specification (excl. wastage) Installation diagram (M97) for Focus D, direct installation |
Size, mm | |||||
| 1200x6000 | 600x600 | 1600x600 | 1800x600 | 2400x600 | 2000x600 | |
| Focus D | 1.05/m² | 2.8/m² | 1.05/m² | 0.95/m² | 0.7/m² | 0.85/m² |
| 1 Connect T24 Main runner HD 7101, installed at 600 mm centres | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² |
| 2 Connect Wall bracket T-profile 0524 | 1 for every row of Main runner |
1 for every row of Main runner |
1 for every row of Main runner |
1 for every row of Main runner |
1 for every row of Main runner |
1 for every row of Main runner |
| 3 Connect Stop clip | 2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
2 for every row of Main runner |
| 4 Connect Direct bracket 1012 | 1.1/m² | 1.1/m² | 1.1/m² | 1.1/m² | 1.1/m² | 1.1/m² |
| 5 Connect Angle trim, fixed at 300 mm centres | as required | as required | as required | as required | as required | as required |
| 6 Connect Shadow-line trim, fixed at 300 mm centres | as required | as required | as required | as required | as required | as required |