For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable.
SYSTEM RANGE
| Size, mm | 600 X 600 |
1200 X 600 |
1200 X 1200 |
XL 1600 X 600 |
XL 1600 X 600 |
XL 2000 X 600 |
XL 2400 X 600 |
| T24 | • | • | • | • | • | • | • |
| T15 | • | • | • | ||||
| Thickness | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
| Inst. diagr. | A | m01 | m01 | m01 | m46 m16 |
m46 m16 |
m46 m16 |
SYSTEM AND PRODUCT DESCRIPTION
The systems consist of Ecophon Focus A tiles and Ecophon Connect grid systems, with an approximate weight of 3 kg/m². The tiles are manufactured from high density glass wool. The visible surface has an Akutex T coating and the back of the tile is covered with glass tissue. The edges are primed. The grid is manufactured from galvanized steel.
ACOUSTICS:
SOUND ABSORPTION: Test results according to EN ISO 354.Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
SOUND INSULATION: Dn,c,w=20 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=21 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
SOUND PRIVACY: AC(1.5)=190 according to ASTM E 1111 and E 1110.
α Practical sound absorption coefficient

| Product | Focus A | |||
| O.d.s. mm | 400 | 200 | 80 | 50 |
| Absorption class | A | A | B | |
| NRC | 0,85 | 0,85 | ||
| S A A | 0,88 | 0,83 | ||

Focus A tile

Section of Focus A system with Connect T24

Focus A system
Technical info
ACCESSIBILITY: The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
CLEANABILITY: Daily dusting and vacuum cleaning. Weekly wet cleaning.
LIGHT EFFICIENCY: White 010, nearest NCS colour sample S 0502-Y, 84% light reflectance (of which more than 99% is diffuse reflection). Colours: See Ecophon colour range.
INFLUENCE OF CLIMATE: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
INDOOR CLIMATE: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6/M3.5.
ENVIRONMENTAL INFLUENCE: Granted the Nordic Swan eco-label. Fully recyclable.
FIRE SAFETY: Reaction-to-fire classifications.
| Country | Standard | Class |
| UK | BS 476 Parts 6&7 | Class 0 |
| Europe | EN 13501-1 | A2-s1,d0 |
The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Functional demands, Fire safety.
MECHANICAL PROPERTIES: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
| Inst. diagr., Size (mm) | Max live load (N) | Min load bearing capacity (N) |
| m01 600x600 | 50 | 160 |
| m16 1800x600 | 20 | - |
| m16 2400x600 | 0 | - |
| m46 1800x600 | 50 | 160 |
| m46 2400x600 | 50 | 160 |
| m16 1600x600 | 40 | - |
| m16 2000x600 | 10 | - |
| m46 2000x600 | 50 | 160 |
| m01 1200x600 | 50 | 160 |
| m01 1200x1200 | 50 | 160 |
| m46 1600x600 | 50 | 160 |
INSTALLATION: Installed according to installation diagrams M01, M16 or M46, which include information regarding minimum overall depth of system.
www.ecophon.com, CADsupport, Product selector, Specification, Maintenance manual
| Quantity specification (excl. wastage) Installation diagram (M46) for Focus A XL |
Size, mm | |||
| 1800x600 | 2400x600 | 1600x600 | 2000x600 | |
| Focus A | 0.95/m² | 0.7/m² | 1.05/m² | 0.85/m² |
| 1 Connect T24 Main runner, installed at 600 mm centres | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² | 1.7 m/m² |
| 2 Connect T24 Cross tee, L=600 mm | 0.6 m/m² | 0.45 m/m² | 0.65 m/m² | 0.5 m/m² |
| 3 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm) | 1.1/m² | 1.1/m² | 1.1/m² | 1.1/m² |
| 4 Connect Hanger clip | 1.1/m² | 1.1/m² | 1.1/m² | 1.1/m² |
| 5 Connect Angle trim, fixed at 300 mm centres | as required | as required | as required | as required |
| 6 Connect Shadow-line trim, fixed at 300 mm centres | as required | as required | as required | as required |
| Quantity specification (excl. wastage) Installation diagram (M01) for Focus A | Size, mm | ||
| 1200x1200 | 1200x600 | 600x600 | |
| Focus A | 0.7/m² | 1.4/m² | 2.8/m² |
| 1 Connect T24 or T15 Main runner, installed at 1200 mm centres | 0.9 m/m² | 0.9 m/m² | 0.9 m/m² |
| 2 Connect T24 or T15 Cross tee, L=1200 mm | 0.9 m/m² | 1.7 m/m² | 1.7 m/m² |
| 3 Connect T24 or T15 Cross tee, L=600 mm | - | - | 0.9/m² |
| 4 Connect Adjustable hanger, installed at 1200 mm centres (max distance from wall 600 mm) | 0,7/m² | 0,7/m² | 0,7/m² |
| 5 Connect Hanger clip | 0,7/m² | 0,7/m² | 0,7/m² |
| 6 For direct installation: Connect Direct bracket, installed at 1200 mm centres | 0,7/m² | 0,7/m² | 0,7/m² |
| 7 Connect Angle trim, fixed at 300 mm centres | as required | as required | as required |
| 8 Connect Shadow-line trim, fixed at 300 mm centres | as required | as required | as required |
| Quantity specification (excl. wastage) Installation diagram (M16) for Focus A XL in corridors |
Size, mm | |||
| 1600x600 | 2000x600 | 2400x600 | 1800x600 | |
| Focus A | 1.05/m² | 0.85/m² | 0.7/m² | 0.95/m² |
| 1 Connect T24 Corridor profile, installed at 600 mm centres | 1.05/m² | 0.85/m² | 0.7/m² | 0.95/m² |
| 2 Connect Angle trim, fixed at 200 mm centres | as required | as required | as required | as required |
| 3 Connect Shadow-line trim, fixed at 200 mm centres | as required | as required | as required | as required |